Info: | Temperature limit |
Data type: | REAL |
Description:
Runtime error if the temperature of the motor temperature sensor on connector X4 TEMP_MOTOR exceeds the limit (see INFO).
Reaction:
See error number 9001
Cause/Remedy:
During the movement stop (see error number 9010), the temperature of the motor increases.
If the movement would be stopped in already in deeper temperatures, the limit temperature (see INFO) would not be exceeded.